3. Determine the Location of the Steam Generators
IMPORTANT! The minimum required access panel is 24 (61 cm) L x 15 (38.1 cm) H. Allow for a
minimum 12 (30.5 cm) space around all sides of the steam generators. Allow for 3/4 (1.9 cm) space
between the generators and the drain pan.
Ensure clearance between the steam lines and any surrounding surfaces.
Allow for access to the steam generators after installation.
Allow for a 12 (30.5 cm) air gap between and on all sides of the generators.
Allow for a drain pan.
For optimum performance, install the steam generators below the level of the steam heads and as
close as possible to the steam heads. The steam generators should be installed within 25 ft (7.62 m)
of the steam heads in a dry, well-ventilated area. They should be installed within 12 (30.5 cm) of
each other.
4. Install the Electrical Supplies
Model K-1697-NA K-1716-NA
Ordering Information
Steam Generator Rating 26 kW (2-13 kW) 30 kW (2-15 kW)
Required Electrical Service
Generator Dedicated Circuit #1 240 V, 80 A, 50/60 Hz 240 V, 90 A, 50/60 Hz
Generator Dedicated Circuit #2 240 V, 80 A, 50/60 Hz 240 V, 90 A, 50/60 Hz
Product Information
Weight 64 lbs (29 kg), 32 lbs (15 kg) each
Size 18 (45.7 cm) x 24 (61 cm) x 13 (33 cm)
17-3/4" (45.1 cm)
Steam Outlet
Water Inlet
11-3/4"
(29.8 cm)
3/4" NPT
Pressure Relief
Field Wiring
Service Box
8-3/8"
(21.3 cm)
12"
(30.5 cm)
Green LED
Diagnostic Light
Minimum required access panel is
24" (61 cm) L x 15" (38.1 cm) H.
Allow for a minimum of 12" (30.5 cm) of
space around all sides of the steam generator.
Allow for the Drain/Spill Pan.
3/4" (1.9 cm) Min
Control
Cable Input
1053777-2-D 6 Kohler Co.