3. Make the Electrical Connections USA and Mexico
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the junction box and whirlpool pump to a properly
grounded, grounding-type duplex receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI)
or Residual Current Device (RCD). Do not remove the grounding pins from the plugs. Do not use
grounding adapters.
NOTE: A label identifying the model number and electrical rating of the whirlpool is located near the
whirlpool pump.
NOTICE: The whirlpool pump and junction box are equipped with two cords and plugs. A qualified
electrician must install a dedicated GFCI- or RCD-protected, 120 V, 15 A, grounded duplex outlet. No
other load should be on this circuit.
Install a duplex electrical outlet behind the bath, and within reach of the 24 (610 mm) power cord.
Plug the whirlpool pump and junction box into this outlet.
NOTE: Make sure the air actuator tubing is securely attached to the pump, and is not kinked or
damaged.
Bond in accordance
with applicable codes.
Junction Box
Power
Supply
24" (610 mm)
Maximum Distance
24" (610 mm)
Maximum Distance
Install a GFCI-protected
120 V, 15 A grounded outlet.
Kohler Co. 7 1204118-2-B