3. Make the Electrical Connections USA and Mexico
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the junction box and blower to a properly grounded,
grounding-type duplex receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or
Residual Current Device (RCD). Do not remove the grounding pins from the plugs. Do not use
grounding adapters.
NOTICE: The blower and junction box are equipped with cords and plugs. A qualified electrician must
install a GFCI- or RCD-protected, 120 V, 15 A, grounded duplex outlet. No other load should be on this
circuit.
Install a duplex electrical outlet behind the bath, at least 1-1/2 (38 mm) above the subfloor, and
within reach of the 24 (610 mm) power cord.
Plug the blower and junction box into this outlet.
Install a GFCI-protected
120 V, 15 A grounded outlet.
Bond in accordance
with applicable codes.
24" (610 mm)
Maximum Distance
Power
Supply
24" (610 mm)
Maximum Distance
Junction Box
Kohler Co. 7 1204119-2-B