4. Install the Electrical Outlet - United States
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
NOTE: For installations in Latin America, go to the Electrical Connections - Latin America section.
NOTICE: The control amplifier is equipped with a cord and plug. All wiring for the control amplifier has
been completed at the factory. A qualified electrician must install a GFCI- or RCD-protected, 120 V, 15 A
grounded outlet. No other load should be on this circuit.
Install a 120 V, 15 A grounded outlet within the wall framing and within 24 (610 mm) of the
planned control amplifier location.
Control
Amplifier
120 V, 15 A
Grounded Outlet
24" (610 mm)
Maximum